CODE No. DESCRIPTIONS
00
Entrance or Office

Pushing the button inside, locks the knob outside. Turning the inside knob or operating key outside releases the button automatically.
10
Passage latch

The latch bolt is operated by the knob from either side at all times.
20
Privacy or Bathroom

The outside knob is always locked by teh push button inside and unlocked by the emergency release outside or by rotating the inside knob or closing the door.
30
Patio

The outside knob is locked by a push button inside and unlocked by rotating the inside knob or closing the door.
80
Exit

The Dead locking latch bolt is operated from the inside only. The outer knob is always fixed.
90
Entrance (Auto locking)

Pushing teh button inside, locks the knob outside. Turning teh inside knob or operating the key outside releases the button automatically. Rotating teh button anticlockwise, locks the door automatically while closing; inside knob is always free.
01 Classroom

No push button inside. It can be locked from outside by rotating the key at 3600 From inside, however, the knob is always free to be opened and thereafter be shut from outside to autolock.No push button inside. It can be locked from outside by rotating the key at 3600 From inside, however, the knob is always free to be opened and thereafter be shut from outside to autolock.

61
Shaft
The Dead locking latch bolt is operated with a key only from the inside, Blank plate outside, the inside knob is always fixed. Key can be provided with Key Alike, Master Key or without bites for the convenience.
70 Hotel-Motel (with emergency key)

Operated by a knob from inside at all times, the outside knob is always fixed. Can be operated by the key except when the push button inside is operated thus shutting out all keys except the emergency key. Inside, the push button provides a double lockout feature by keeping the indicator thrown. Turning the knob inside or closing the door releases the indicator and the shut out feature. Locks can be provided with Floor Master Key, Grand Master Key, Great Grand Master Key & Emergency Key as per the requirement.
71 Hotel-Motel (with emergency key & room sealing facility)

Operated by a knob from inside at all times, the outside knob is always fixed. Can be operated by the key except when the push button inside is operated thus shutting out all keys except the emergency key. Inside, the push button provides a double lockout feature by keeping the indicator thrown. Turning the knob inside or closing the door releases the indicator and the shut out feature. But rotating the Inside Push Button anti clockwise, with the help of room sealing key, locks the Indicator thus room could be sealed even if the guest is outside. Locks can be provided with Floor Master Key, Grand Master Key, Great Grand Master Key & Emergency Key as per the requirement.

50
storeroom or Service

Operated by a key from the outside or by rotating the inside knob. The outside knob is always fixed.
60
Interconnecting or Twin Communicating

The Dead locking latch bolt is operated with a key only from the inside, blank plate outside, the inside knob is always fixed.
40
Single Dummy Trim

Sinngle Dummy trim is only one side of the door. Pull only.
note : Dimensions in drawings are indicative, ACME reserves teh right to introduce technical and aesthetical changes without prior notice.




 
 
 
 
 
 
»